FDA UDI
In Commercial Distribution
🇺🇸 United States
RHEUMATOID FACTOR TOTAL
DI: 04260157080263
·
Model: ORG522T
·
ORGENTEC Diagnostika GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- RHEUMATOID FACTOR TOTAL
- Primary DI
- 04260157080263
- Version / Model
- ORG522T
- Catalog Number
- ORG522T
- Company Name
- ORGENTEC Diagnostika GmbH
- Labeler DUNS
- 328133103
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-08-31
- Public Version
- 2
- Public Version Date
- 2018-03-29
- Public Version Status
- Update
- Public Device Record Key
- 3c3f366a-b994-4b20-a5ed-ceda7a7f8335
Device Description
Rheumatoid Factor Total is an ELISA test system for the quantitative measurement of IgG, IgM and IgA class rheumatoid factor in human serum or plasma. This product is intended for professional in vitro diagnostic use only as an aid in the diagnosis of Rheumatoid Arthritis, in conjunction with other laboratory and clinical findings.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DHR | System, Test, Rheumatoid Factor | Immunology | 866.5775 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 55073 | Proteinase 3 anti-neutrophil cytoplasmic antibody (PR3-ANCA) IVD, kit, multiplex | A collection of reagents and other associated materials intended to be used for the qualitative and/or quantitative detection of anti-neutrophil cytoplasmic antibodies (ANCA) to proteinase 3 (PR3) in a clinical specimen, using a multiplex method. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04260157080263 | GS1 |
Customer Contacts
- Phone
- +49061319258
- [email protected]
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 2 – 8 Degrees Celsius