SpO2 Adapter, small, 10/box
DI: 04255629200577
·
Model: SpO2 Adapter, small, 10/box
·
MIPM Mammendorfer Institut für Physik und Medizin GmbH
Product Codes
1
GMDN Terms
1
Identifiers
3
Pkg Device Count
10
Basic Information
- Brand Name
- SpO2 Adapter, small, 10/box
- Primary DI
- 04255629200577
- Version / Model
- SpO2 Adapter, small, 10/box
- Catalog Number
- 5010024
- Company Name
- MIPM Mammendorfer Institut für Physik und Medizin GmbH
- Labeler DUNS
- 324416379
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 10
- Record Status
- Published
- Publish Date
- 2023-12-14
- Public Version
- 1
- Public Version Date
- 2023-12-22
- Public Version Status
- New
- Public Device Record Key
- 1a7e870b-96a7-4a7b-b256-97a78ed048cd
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MWI | Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms) | Cardiovascular | 870.2300 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47582 | Pulse Co-oximeter probe, reusable | A photoelectric component of a pulse Co-oximeter that is applied externally to a body part (e.g., a fingertip for adults, the hand or foot for neonates), for the transcutaneous multiwave measurement of carboxy-haemoglobin saturation (SpCO) and typically several other related parameters such as haemoglobin oxygen saturation (SpO2), methaemoglobin saturation (SpMet), haemoglobin concentration (SpHb), haematocrit, and pulse rate using light detection. Signals from the probe, produced by a light-emitting diode (LED) and a receiving detector, are used to calculate results which are digitally displayed on the Co-oximeter's computerized unit. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Unit of Use | 04255629200874 | GS1 | ||||
| Primary | 04255629200577 | GS1 | ||||
| Previous | EMIP50100240 | HIBCC |
Customer Contacts
- Phone
- +49814592090
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K142032 | 000 |