FDA UDI
Not in Commercial Distribution
🇺🇸 United States
DANmed
DI: 04251351116896
·
Model: LMZ-121-120
·
DANNORITZER Medizintechnik GmbH & Co. KG
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- DANmed
- Primary DI
- 04251351116896
- Version / Model
- LMZ-121-120
- Catalog Number
- LMZ-121-120
- Company Name
- DANNORITZER Medizintechnik GmbH & Co. KG
- Labeler DUNS
- 314648911
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-03-06
- Public Version
- 4
- Public Version Date
- 2022-09-07
- Public Version Status
- Update
- Public Device Record Key
- 7ca34f49-65b5-4e1e-a57e-6eaa6a68fb5d
- Distribution End Date
- 2022-09-06
Device Description
LAP-Insert only, Ø5mm, l=200mm Grasp. forceps MARYLAND, serrated, d/a Tip- length: 13,5mm
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GEI | Electrosurgical, cutting & coagulation & accessories | General, Plastic Surgery | 878.4400 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35080 | Rigid endoscopic tissue manipulation forceps, reusable | A rigid, hand-held manual surgical instrument designed to be introduced through the working channel of an endoscope and/or an endoscopic port (e.g., laparoscopic port) primarily for grasping and manipulating tissues during endoscopic surgery. It has proximal controls (e.g., scissors-like handles), a rigid long slender shaft, and distal grasping jaws; it is not an electrosurgical device and is not dedicated to biopsy. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04251351116896 | GS1 |
Customer Contacts
- Phone
- +497461962390
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K052759 | 000 |