FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Jaeger
DI: 04250892900322
·
Model: V-173103
·
Vyaire Medical GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Jaeger
- Primary DI
- 04250892900322
- Version / Model
- V-173103
- Catalog Number
- V-173103
- Company Name
- Vyaire Medical GmbH
- Labeler DUNS
- 329769991
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-08-02
- Public Version
- 5
- Public Version Date
- 2021-03-16
- Public Version Status
- Update
- Public Device Record Key
- 6004e415-c59a-4a45-8eed-e013f6892951
- Distribution End Date
- 2018-07-05
Device Description
MasterScreen CPX
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| BZC | Calculator, Pulmonary Function Data | Anesthesiology | 868.1880 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 36146 | Cardiopulmonary stress exercise monitoring system | An assembly of devices intended to noninvasively assess the cardiopulmonary response to exercise or measure of energy expenditure using indirect calorimetry. Breath by breath measurements of flow, oxygen (O2) uptake, and carbon dioxide (CO2) production are performed by O2 and CO2 analysers during exercise, along with the measurement of vital parameters. A mask, mouthpiece, or hood is attached to tubing and connected from the patient to the gas analysers while exercise is being performed using a particular device (e.g., an ergometer). The system typically monitors functions [e.g., provides continuous electrocardiogram (ECG)], provides control of the workload, and displays and prints results. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04250892900322 | GS1 |
Customer Contacts
- Phone
- +499314972127
- [email protected]
Storage Conditions
- Type
- Storage Environment Humidity
- Temperature Range
- 15 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- -20 – 50 Degrees Celsius