FDA UDI
In Commercial Distribution
🇺🇸 United States
Camsource®
DI: 04250337116110
·
Model: CSFHD01SO
·
Joimax GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Camsource®
- Primary DI
- 04250337116110
- Version / Model
- CSFHD01SO
- Catalog Number
- CSFHD01SO
- Company Name
- Joimax GmbH
- Labeler DUNS
- 344267187
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2022-12-30
- Public Version
- 1
- Public Version Date
- 2023-01-09
- Public Version Status
- New
- Public Device Record Key
- 34ab3b1a-1e76-4eda-af85-879d146c2874
Device Description
Camsource® LED System Ocular
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FWF | CAMERA, TELEVISION, ENDOSCOPIC, WITHOUT AUDIO | General, Plastic Surgery | 878.4160 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 32579 | Spinal endoscopic-access system | An assembly of devices used to gain access to the spine by dilation of the overlying tissues for the placement and support of an endoscope. It typically includes the endoscope, a light source, a fibreoptic light cable, a camera control unit, a camera, and cannulae (portals). It is used for posterior or anterior access and visualization of a surgical area of the cervical, thoracic, or lumbar spine, allowing the surgeon to perform a procedure such as, a discectomy, nucleotomy, spinal fusion, spinal decompression, foraminotomy, or insertion of spinal implants. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04250337116110 | GS1 |
Customer Contacts
- Phone
- +497212551407010
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Combined camera and light source system |
Storage Conditions
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 90 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- -25 – 70 Degrees Celsius