FDA UDI
In Commercial Distribution
🇺🇸 United States
Hermann Medizintechnik GmbH
DI: 04059453044570
·
Model: H85-027-030
·
Hermann Medizintechnik GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Hermann Medizintechnik GmbH
- Primary DI
- 04059453044570
- Version / Model
- H85-027-030
- Company Name
- Hermann Medizintechnik GmbH
- Labeler DUNS
- 324868165
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2019-08-28
- Public Version
- 3
- Public Version Date
- 2023-11-17
- Public Version Status
- Update
- Public Device Record Key
- 3f3a7b2c-0159-43e8-a5f5-b30eaec6f8d3
Device Description
Hysteroscope HD, Ø 2,7mm,view angle 30°,WL 302mm, autoclavable
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GCJ | Laparoscope, general & plastic surgery | Gastroenterology, Urology | 876.1500 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 36628 | Rigid optical hysteroscope | An endoscope with a rigid inserted portion intended for the visual examination and treatment of the canal of the cervix and the uterine cavity (uterus). It is inserted through the vagina during hysteroscopy. Anatomical images are transmitted to the user through relayed lens optics or a fibreoptic bundle. Distention of the uterus with, e.g., carbon dioxide(CO2) gas may be used to improve viewing. This device is typically used to evaluate/treat fibroids (myomas), polyps, or causes of severe cramping (dysmenorrhea), heavy menstrual periods (menorrhagia), and bleeding between periods (metrorrhagia). This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04059453044570 | GS1 |
Customer Contacts
- Phone
- +49746299670
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K051610 | 000 |