FDA UDI
In Commercial Distribution
🇺🇸 United States
Fraxion
DI: 04056719001544
·
Model: P10106-212
·
3C-Medical Intelligence GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Fraxion
- Primary DI
- 04056719001544
- Version / Model
- P10106-212
- Catalog Number
- P10106-212
- Company Name
- 3C-Medical Intelligence GmbH
- Labeler DUNS
- 314546664
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-08-23
- Public Version
- 7
- Public Version Date
- 2023-12-15
- Public Version Status
- Update
- Public Device Record Key
- 5cbc3520-751b-4752-a9fa-a44e83b0925b
Device Description
The FRAXION™ Vacuum cushions are formed to the patients head and enable highly accurate patient repositioning. Each cushion will be moulded individually for each patient and will be stored together with all patient-specific parts in the storage box for the whole treatment time.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| IYE | Accelerator, Linear, Medical | Radiology | 892.5050 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61128 | Stereotactic radiosurgical/radiotherapy arch head frame | A non-sterile device intended to be used to position and immobilize a patient’s head for reproducible positioning during radiation treatment planning, stereotactic radiotherapy (SRT), and stereotactic radiosurgery (SRS), on all parts of the brain, head, and neck. It is in the form of an arched frame to which can be attached various components (e.g., mouthpiece, nasion cushion) that non-invasively contact the patient to serve as points of reference, and which is typically attached to a base plate, couch top, or overlay. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04056719001544 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K112210 | 000 |