FDA UDI
In Commercial Distribution
🇺🇸 United States
ENDOCAM
DI: 04055207066188
·
Model: 5522101
·
Richard Wolf GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- ENDOCAM
- Primary DI
- 04055207066188
- Version / Model
- 5522101
- Catalog Number
- 5522101
- Company Name
- Richard Wolf GmbH
- Labeler DUNS
- 315304071
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-10-21
- Public Version
- 1
- Public Version Date
- 2021-10-29
- Public Version Status
- New
- Public Device Record Key
- 3c9654be-9387-4eaa-b7e9-81c98cd6405d
Device Description
D CAMERA CONTROLLER for connection of sensor endoscopes, Output: 1x HDMI, 1x SDI, Capturing video/images on USB, Resolution: 1920x1080 (HDMI, SDI), 1280x1024 (HDMI), Revolutions: 100-240VAC, 50/60Hz, Dim. (wxhxd) 200x60x220mm
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FET | Endoscopic video imaging system/component, gastroenterology-urology | Gastroenterology, Urology | 876.1500 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 18034 | Endoscopic video image processing unit | An electrically-powered device designed to receive and process the electronic signals sent from a video endoscope or endoscopic video camera; it does not include the endoscope nor light source and is not designed to control the endoscope. It may have additional features which compensate for/enhance the colour and light qualities provided. The resulting picture images are sent to and shown on a visual display unit (VDU), typically to assist the endoscope operator with an ongoing intervention and often to allow the patient visualization of the process; the images can be recorded on a video recorder or stored on computerized media. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04055207066188 | GS1 |
Customer Contacts
- Phone
- +497043350
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K211332 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- -20 – 60 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 90 Percent (%) Relative Humidity