FDA UDI
In Commercial Distribution
🇺🇸 United States
PIRANHA
DI: 04055207063415
·
Model: 49700103
·
Richard Wolf GmbH
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
3
Basic Information
- Brand Name
- PIRANHA
- Primary DI
- 04055207063415
- Version / Model
- 49700103
- Catalog Number
- 49700103
- Company Name
- Richard Wolf GmbH
- Labeler DUNS
- 315304071
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 3
- Record Status
- Published
- Publish Date
- 2017-06-28
- Public Version
- 9
- Public Version Date
- 2022-02-25
- Public Version Status
- Update
- Public Device Record Key
- 05e63616-946d-4745-bc40-7f469b7119d8
Device Description
ROTATIONS-MORCELLATOR Ø 4.8MM WL 385MM for MORCESCOPE Storz, for morcellation following laser prostate enucleation, sterile
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FJL | Resectoscope | Gastroenterology, Urology | 876.1500 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46732 | Tissue morcellation system handpiece, line-powered | A hand-held component of a tissue morcellation system intended to be used to mechanically cut (slice), core (cut a hole into), peel (remove surface), and extract selected tissue from the body during surgery. It consists of a high-speed rotating blade in a holder and is connected to a line-powered control unit for the transfer of electrical energy or rotational power (via an electrical or remote drive cable); a handpiece obturator, and a disposable remote drive cable may be included. Resected tissue may be removed through suction or manually with a grasping instrument. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04055207063415 | GS1 | ||||
| Unit of Use | 04055207049730 | GS1 |
Customer Contacts
- Phone
- +497043350
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 385 | Millimeter | |
| Outer Diameter | 4.8 | Millimeter |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 5 – 30 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 0 – 70 Percent (%) Relative Humidity