FDA UDI
Not in Commercial Distribution
🇺🇸 United States
ARTHROLINE
DI: 04055207034576
·
Model: 891432101
·
Richard Wolf GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- ARTHROLINE
- Primary DI
- 04055207034576
- Version / Model
- 891432101
- Catalog Number
- 891432101
- Company Name
- Richard Wolf GmbH
- Labeler DUNS
- 315304071
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2022-08-12
- Public Version
- 2
- Public Version Date
- 2024-02-29
- Public Version Status
- Update
- Public Device Record Key
- f3d25824-466c-4537-a6f2-78ec118e4e9e
- Distribution End Date
- 2024-01-01
Device Description
PUNCH WL 180MM H 1.6MM jaw section curved upward, sheath curved to the left, reusable
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| NBH | Accessories, arthroscopic | Orthopedic | 888.1100 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46421 | Rigid endoscopic scissors, reusable | A hand-held rigid device used in combination with a dedicated endoscope and intended to cut tissue or sutures during an endoscopic procedure. It is typically constructed of stainless steel and is designed as a long pair of parallel sliding arms whose distal end is equipped with a pair of mechanical (i.e., not electrosurgical) cutting blades operated through a ringed handle at the proximal end. It is typically introduced into the body cavity through the working channel of the endoscope. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04055207034576 | GS1 |
Customer Contacts
- Phone
- +497043350
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Height | 1.6 | Millimeter | |
| Length | 180 | Millimeter |