FDA UDI
In Commercial Distribution
🇺🇸 United States
NA
DI: 04055207021989
·
Model: 8919331
·
Richard Wolf GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- NA
- Primary DI
- 04055207021989
- Version / Model
- 8919331
- Catalog Number
- 8919.331
- Company Name
- Richard Wolf GmbH
- Labeler DUNS
- 315304071
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-27
- Public Version
- 7
- Public Version Date
- 2022-08-03
- Public Version Status
- Update
- Public Device Record Key
- e34e3d63-5b3c-4e54-be14-17b2d939c618
Device Description
TROCAR SLEEVE STRAI. CAP 5.5MM WL 62MM flexible plastic sheath with thread, distal tip straight, with membrane valve, reusable
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FBQ | Trocar, gastro-urology | Gastroenterology, Urology | 876.5090 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 37148 | Laparoscopic access cannula, reusable | A single-lumen surgical device intended to be percutaneously inserted through the abdominal wall to create an access port for a laparoscope/laparoscopic instrument during laparoscopy. The cannula is often provided with a shut-off valve for gas/fluid supply, and other sealing devices (e.g., dedicated seals/rings, caps, valves), to prevent insufflation gas leakage whilst allowing entry of instruments. It may include a sharp or blunt trocar blade to assist introduction and/or puncture the abdominal wall; if the trocar is included it may be referred to as a trocar or trocar assembly. It is available in a variety of dimensions and/or designs. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04055207021989 | GS1 |
Customer Contacts
- Phone
- +497043350
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 62 | Millimeter |