FDA UDI
In Commercial Distribution
🇺🇸 United States
NA
DI: 04055207017074
·
Model: 8416031
·
Richard Wolf GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- NA
- Primary DI
- 04055207017074
- Version / Model
- 8416031
- Catalog Number
- 8416031
- Company Name
- Richard Wolf GmbH
- Labeler DUNS
- 315304071
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-23
- Public Version
- 4
- Public Version Date
- 2021-04-27
- Public Version Status
- Update
- Public Device Record Key
- 430c7228-d753-4282-b157-0d8678299d69
Device Description
CUTTING ELECTRODE MONO 14.5FR 0° for resectoscopes, telescope Ø 4mm, for sheaths, intermittent irrigation, 14.5, Fr, loop: round, stem color yellow, PACK=1 PC, for MIDI-size resectoscope, unsterile, reusable
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FAS | ELECTRODE, ELECTROSURGICAL, ACTIVE, UROLOGICAL | Gastroenterology, Urology | 876.4300 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 33596 | Endoscopic electrosurgical handpiece/electrode, monopolar, reusable | An electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a monopolar electrode, intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery. It includes a long thin electrode connected to the handpiece, and may include a lumen for suction/irrigation; it is available in a variety of forms (e.g., forceps or snare with ring handles, rigid probe with controls) and requires a patient contact return electrode to complete the circuit. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04055207017074 | GS1 |
Customer Contacts
- Phone
- +497043350
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Outer Diameter | 4.83333333333 | Millimeter | |
| Angle | 0 | degree |