FDA UDI
In Commercial Distribution
🇺🇸 United States
QIAstat-Dx® Rise
DI: 04053228041849
·
Model: 1
·
QIAGEN GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- QIAstat-Dx® Rise
- Primary DI
- 04053228041849
- Version / Model
- 1
- Catalog Number
- 9003163
- Company Name
- QIAGEN GmbH
- Labeler DUNS
- 317103745
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2025-09-05
- Public Version
- 1
- Public Version Date
- 2025-09-15
- Public Version Status
- New
- Public Device Record Key
- 1ae972a4-fa3b-4fa3-b4df-1b41d0a665a4
Device Description
The QIAstat-Dx Rise system is intended as an in-vitro diagnostic device for use with QIAstat-Dx in-vitro diagnostic assays indicated for use with QIAstat-Dx Rise and provides full automation from sample preparation to real-time PCR detection for molecular applications. The system is designed for professional use only and it is not a device for self-testing or near-patient testing.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| OOI | Real Time Nucleic Acid Amplification System | Clinical Chemistry | 862.2570 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 48031 | Thermal cycler nucleic acid amplification analyser IVD, laboratory | An electrically-powered automated or semi-automated laboratory instrument intended to amplify target deoxyribonucleic acid (DNA) or ribonucleic acid (RNA) in a clinical specimen using heat-stable polymerase enzymes and cycles of repeated heating and cooling (i.e., thermal cycling) to replicate a product [i.e., a polymerase chain reaction (PCR)]. Amplified product is detected and/or quantified using oligonucleotide markers as it is produced (i.e., in real-time) or at the end-point. The analyser may also isolate, extract and/or prepare nucleic acid from the clinical specimen and/or culture isolate prior to amplification. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04053228041849 | GS1 |
Customer Contacts
- Phone
- 8003627737
- [email protected]
Storage Conditions
- Type
- Handling Environment Temperature
- Temperature Range
- 0 – 55 Degrees Celsius