FDA UDI
In Commercial Distribution
🇺🇸 United States
LifeStent® XL Vascular & Biliary Stent
DI: 04049519001128
·
Model: EX061201CS
·
Bard Peripheral Vascular, Inc.
Product Codes
2
GMDN Terms
2
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- LifeStent® XL Vascular & Biliary Stent
- Primary DI
- 04049519001128
- Version / Model
- EX061201CS
- Catalog Number
- EX061201CS
- Company Name
- Bard Peripheral Vascular, Inc.
- Labeler DUNS
- 135057938
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2014-09-17
- Public Version
- 6
- Public Version Date
- 2024-01-04
- Public Version Status
- Update
- Public Device Record Key
- 4d1b5fba-b585-4b4b-9eda-d1cad3c2cb4a
Device Description
BARD® LIFESTENT® XL Vascular and Biliary Stent System 6 mm x 120 mm (80 cm delivery catheter)
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FGE | CATHETER, BILIARY, DIAGNOSTIC | Gastroenterology, Urology | 876.5010 | 2 |
| NIP | STENT, SUPERFICIAL FEMORAL ARTERY | Unknown | 3 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 43691 | Bare-metal biliary stent | A non-bioabsorbable tubular device intended to be implanted in an obstructed biliary duct (e.g., common bile duct) to maintain luminal patency; it is not intended for vascular implantation. It may be a mesh structure or a continuous tube and is made entirely of metal [e.g., high-grade stainless steel, cobalt-chrome (Co-Cr), nickel-titanium alloy (Nitinol)]. It may be expandable in situ (e.g., with a balloon catheter or self-expands) and disposable devices intended to assist implantation may be included. | Yes | Active |
| 47932 | Peripheral artery stent, bare-metal | A non-bioabsorbable tubular device intended to be implanted in a peripheral artery (excludes aorta, coronary, and intracranial arteries) to indefinitely maintain patency and improve luminal diameter in patients with atherosclerotic disease, or following the recanalization of a total occlusion. It may additionally be intended to be implanted in an obstructed biliary duct; it is not dedicated to carotid artery implantation. The stent is made entirely of metal [e.g., nickel-titanium alloy (Nitinol) mesh structure] and is typically implanted by a dedicated instrument where it self-expands upon release or is balloon expanded. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04049519001128 | GS1 |
Customer Contacts
- Phone
- +1(800)321-4254
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Implant Length,120 Millimeter | ||
| Device Size Text, specify | Implant Diameter,6 Millimeter | ||
| Device Size Text, specify | Catheter Length,80 Centimeter |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- High: 60 Degrees Celsius
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep dry
- Type
- Special Storage Condition, Specify
- Special Conditions
- Store in a cool, dry, dark place.
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep away from sunlight