FDA UDI
In Commercial Distribution
🇺🇸 United States
LifeStent® XL Vascular Stent
DI: 04049519001005
·
Model: EX071703CS
·
Bard Peripheral Vascular, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- LifeStent® XL Vascular Stent
- Primary DI
- 04049519001005
- Version / Model
- EX071703CS
- Catalog Number
- EX071703CS
- Company Name
- Bard Peripheral Vascular, Inc.
- Labeler DUNS
- 135057938
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2014-09-12
- Public Version
- 7
- Public Version Date
- 2024-12-11
- Public Version Status
- Update
- Public Device Record Key
- ac731cb6-5f7a-4094-9935-0db55599bade
Device Description
BARD® LIFESTENT® XL Vascular Stent System 7 mm x 170 mm (130 cm delivery catheter)
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| NIP | STENT, SUPERFICIAL FEMORAL ARTERY | Unknown | 3 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47932 | Peripheral artery stent, bare-metal | A non-bioabsorbable tubular device intended to be implanted in a peripheral artery (excludes aorta, coronary, pulmonary, and intracranial arteries) to indefinitely maintain patency and improve luminal diameter in patients with atherosclerotic disease, or following the recanalization of a total occlusion. It may additionally be intended to be implanted in an obstructed biliary duct; it is not dedicated to carotid artery implantation, and not intended for connection with an aortic stent. It is made entirely of metal [e.g., Nitinol alloy mesh structure] and typically implanted by a dedicated instrument where it self-expands upon release or is balloon expanded. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04049519001005 | GS1 |
Customer Contacts
- Phone
- +1(800)321-4254
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Implant Diameter,7 Millimeter | ||
| Device Size Text, specify | Implant Length,170 Millimeter | ||
| Device Size Text, specify | Catheter Length,130 Centimeter |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep dry
- Type
- Special Storage Condition, Specify
- Special Conditions
- Store in a cool, dry, dark place.
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep away from sunlight
- Type
- Storage Environment Temperature
- Temperature Range
- High: 60 Degrees Celsius