Basic Information
- Brand Name
- EcoBalloonDuo DIL-BI + URO
- Primary DI
- 04048223132906
- Version / Model
- 1285-50-28S
- Catalog Number
- 1285-50-28S
- Company Name
- Pajunk GmbH Medizintechnologie
- Labeler DUNS
- 317654283
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2025-06-17
- Public Version
- 2
- Public Version Date
- 2025-06-26
- Public Version Status
- Update
- Public Device Record Key
- 5063d3ca-7587-4e1f-b893-d7c02143dffe
Device Description
EcoBalloonDuo DIL-BI + URO Bilateral double balloon set Ø 11mm for extraperitoneal surgery,
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GCJ | Laparoscope, general & plastic surgery | Gastroenterology, Urology | 876.1500 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 45342 | Laparoscopic access cannula anchor, single-use | A small, sterile, luminal device designed to enable a laparoscopic access cannula (port) to be secured to the skin/tissue of an incision site during a laparoscopic surgical procedure. The outer surface is typically textured/ribbed and intended to grip the tissue whilst the laparoscopic access cannula is inserted through the device lumen and fixed at the required insertion depth using a clamping/locking mechanism. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 04048223133163 | GS1 | 5 | In Commercial Distribution | ||
| Primary | 04048223132906 | GS1 | ||||
| Previous | 04048223058015 | GS1 |
Customer Contacts
- Phone
- +1 770-493-6832
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K090631 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 10 – 30 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 20 – 65 Percent (%) Relative Humidity