FDA UDI
In Commercial Distribution
🇺🇸 United States
VERESS
DI: 04048223077672
·
Model: 1206-20150
·
Pajunk GmbH Medizintechnologie
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- VERESS
- Primary DI
- 04048223077672
- Version / Model
- 1206-20150
- Catalog Number
- 1206-20150
- Company Name
- Pajunk GmbH Medizintechnologie
- Labeler DUNS
- 317654283
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-04-02
- Public Version
- 3
- Public Version Date
- 2021-07-12
- Public Version Status
- Update
- Public Device Record Key
- 0357c852-4547-47bb-81a5-0a625c6c7ffc
Device Description
1206-20150
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HET | LAPAROSCOPE, GYNECOLOGIC (AND ACCESSORIES) | Obstetrics/Gynecology | 884.1720 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46329 | Spring-loaded pneumoperitoneum needle, reusable | A slender, sharply-pointed metal tube designed to introduce or remove gas from the peritoneal cavity as a therapeutic or surgical/radiological procedural method. It is often inserted into the peritoneal cavity for the purpose of insufflation [e.g., with carbon dioxide (CO2)] to establish pneumoperitoneum prior to abdominal endoscopy. It is equipped with a spring-loaded, round-tipped obturator that extends from the tube when the device does not encounter resistance (i.e., when the cavity has been reached) to prevent damage from the sharp point. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04048223077672 | GS1 | ||||
| Previous | 04048223027882 | GS1 |
Customer Contacts
- Phone
- +1 770-493-6832
- [email protected]
Storage Conditions
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 65 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- 10 – 30 Degrees Celsius