FDA UDI
In Commercial Distribution
🇺🇸 United States
MULTISTIM ECO
DI: 04048223075913
·
Model: 1151-94-21
·
Pajunk GmbH Medizintechnologie
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- MULTISTIM ECO
- Primary DI
- 04048223075913
- Version / Model
- 1151-94-21
- Catalog Number
- 1151-94-21
- Company Name
- Pajunk GmbH Medizintechnologie
- Labeler DUNS
- 317654283
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-04-02
- Public Version
- 3
- Public Version Date
- 2021-07-12
- Public Version Status
- Update
- Public Device Record Key
- addc36b8-6bd9-4d30-9d29-025e1357b442
Device Description
1151-94-21
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| BXN | STIMULATOR, NERVE, BATTERY-POWERED | Anesthesiology | 868.2775 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47487 | Electrical-only medical device connection cable, reusable | A non-patient-contact, insulated, electrical cord with a connector (plug) at both ends designed to transmit electrical power and/or signal (data) between medical devices (e.g., to connect a lead, electrical catheter, handpiece, or monitor to a parent device). It is not intended to connect directly to patient-worn electrodes (i.e., it is not a lead), is not intended to connect to the mains (i.e., not a mains power cable), does not generate any type of power and/or signal, and has no additional non-electrical conducting or processing functionality. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04048223075913 | GS1 | ||||
| Previous | 04048223035320 | GS1 |
Customer Contacts
- Phone
- +1 770-493-6832
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K162086 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 10 – 30 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 65 Percent (%) Relative Humidity