FDA UDI
In Commercial Distribution
🇺🇸 United States
TOSCA II
DI: 04047844007624
·
Model: Cervical plate, 4-level
·
SIGNUS Medizintechnik GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- TOSCA II
- Primary DI
- 04047844007624
- Version / Model
- Cervical plate, 4-level
- Catalog Number
- F4-100
- Company Name
- SIGNUS Medizintechnik GmbH
- Labeler DUNS
- 344203948
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-09-24
- Public Version
- 4
- Public Version Date
- 2023-09-18
- Public Version Status
- Update
- Public Device Record Key
- 2c72e3b3-87de-4320-bddd-cd991f4446d6
Device Description
The TOSCA II Anterior Cervical Plate System comprises plate and screw components in a variety of sizes and lengths. Variable angle screws and a center graft screw are offered.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| KWQ | Appliance, Fixation, Spinal Intervertebral Body | Orthopedic | 888.3060 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46653 | Spinal fixation plate, non-bioabsorbable | A small, implantable, non-customized sheet of solid material intended to be attached to the spine with screws for spinal immobilization; it is made of a material that is not chemically degraded or absorbed via natural body processes (includes implant grade metal such as surgical steel, titanium alloy, or carbon fibre). The device is typically used to provide immobilization and stabilization of spinal segments in the treatment of various spinal instabilities or deformities (e.g., during anterior/posterior cervical, anterior/posterior lumbar, thoracolumbar, and occipital fixation procedures). | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04047844007624 | GS1 |
Customer Contacts
- Phone
- +49602391660
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | 100mm |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 0 – 35 Degrees Celsius