FDA UDI
In Commercial Distribution
🇺🇸 United States
TOSCA
DI: 04047844002841
·
Model: Fixed angle expansion screw
·
SIGNUS Medizintechnik GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- TOSCA
- Primary DI
- 04047844002841
- Version / Model
- Fixed angle expansion screw
- Catalog Number
- DX-4512
- Company Name
- SIGNUS Medizintechnik GmbH
- Labeler DUNS
- 344203948
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-09-24
- Public Version
- 7
- Public Version Date
- 2023-09-18
- Public Version Status
- Update
- Public Device Record Key
- 1e8322d1-6dc7-421e-8967-c3078988fc98
Device Description
The TOSCA Anterior Cervical Plate System consits of various sizes of bone plates and screws that are either fixed angle or variable angle. The screws are used to secure the plates to the vertebral bodies of the cervical spine through the anterior approach. The plates and screws are made from Titanium alloy Ti6Al4V, are in conformance with ASTM F136, and are supplied non-sterile.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| KWQ | Appliance, Fixation, Spinal Intervertebral Body | Orthopedic | 888.3060 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46653 | Spinal fixation plate, non-bioabsorbable | A small, implantable, non-customized sheet of solid material intended to be attached to the spine with screws for spinal immobilization; it is made of a material that is not chemically degraded or absorbed via natural body processes (includes implant grade metal such as surgical steel, titanium alloy, or carbon fibre). The device is typically used to provide immobilization and stabilization of spinal segments in the treatment of various spinal instabilities or deformities (e.g., during anterior/posterior cervical, anterior/posterior lumbar, thoracolumbar, and occipital fixation procedures). | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04047844002841 | GS1 |
Customer Contacts
- Phone
- +49602391660
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K043082 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Ø4,5x12mm |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 0 – 35 Degrees Celsius