FDA UDI
In Commercial Distribution
🇺🇸 United States
Combined Spinal & Epidural
DI: 04046964940637
·
Model: 339115
·
B. BRAUN MEDICAL INC.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
10
Basic Information
- Brand Name
- Combined Spinal & Epidural
- Primary DI
- 04046964940637
- Version / Model
- 339115
- Catalog Number
- 339115
- Company Name
- B. BRAUN MEDICAL INC.
- Labeler DUNS
- 002397347
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 10
- Record Status
- Published
- Publish Date
- 2016-12-23
- Public Version
- 6
- Public Version Date
- 2020-10-14
- Public Version Status
- Update
- Public Device Record Key
- 2fc10e51-dc79-46e1-9976-0b29bbf26e8f
Device Description
NES1827KN SPINAL/EPIDURAL TRAY NRFIT
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| OGE | Epidural anesthesia kit | Anesthesiology | 868.5120 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46308 | Epidural/intrathecal anaesthesia set, non-medicated | A dual-purpose collection of devices intended for the administration of an analgesic or anaesthetic agent (not included) to the intrathecal space and to the epidural space for the management of pain. It includes both a spinal needle and an epidural needle with additional devices utilized for the procedure (e.g., dressings, syringe) and may include an epidural catheter for continuous-administration. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04046964940637 | GS1 | ||||
| Unit of Use | 04046964940620 | GS1 |
Customer Contacts
- Phone
- +1(800)227-2862
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Gauge (Catheter) : 20 | ||
| Device Size Text, specify | Gauge epidural needle : 18 | ||
| Device Size Text, specify | Gauge spinal needle : 27 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 20 – 25 Degrees Celsius
- Type
- Handling Environment Temperature
- Temperature Range
- 1 – 40 Degrees Celsius