FDA UDI
Not in Commercial Distribution
🇺🇸 United States
TYSHAK X™
DI: 04046964313240
·
Model: 618308
·
B BRAUN INTERVENTIONAL SYSTEMS, INC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- TYSHAK X™
- Primary DI
- 04046964313240
- Version / Model
- 618308
- Catalog Number
- 618308
- Company Name
- B BRAUN INTERVENTIONAL SYSTEMS, INC
- Labeler DUNS
- 784259751
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-08-09
- Public Version
- 7
- Public Version Date
- 2022-11-02
- Public Version Status
- Update
- Public Device Record Key
- 19ba1412-6ddd-40e2-9791-45b9ebef2eb0
- Distribution End Date
- 2021-08-04
Device Description
TYSHAK-X 9X5X6X6X100X.035 PDC308
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DQY | CATHETER, PERCUTANEOUS | Cardiovascular | 870.1250 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 17453 | Cardiac valvuloplasty catheter | A sterile flexible tube with an inflatable balloon designed to perform plastic or restorative surgery on a cardiac valve, i.e., for the dilatation of atrioventricular, aortic, and pulmonary trunk valves. It is typically used for the percutaneous dilatation of commissural fusion in stenotic mitral valves and for annular, cuspal, and calcific nodular fractures, to improve cuspal mobility in adult calcific aortic stenosis, and for leaflet tearing in pulmonic valve stenosis. It may also be used for percutaneous balloon pericardiotomy. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04046964313240 | GS1 |
Customer Contacts
- Phone
- +1(877)836-2228
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K022722 | 000 |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- ROOM TEMP AWAY FROM SUNLIGHT
- Type
- Special Storage Condition, Specify