FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Multi-Track™
DI: 04046964312854
·
Model: 615008
·
B BRAUN INTERVENTIONAL SYSTEMS, INC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Multi-Track™
- Primary DI
- 04046964312854
- Version / Model
- 615008
- Catalog Number
- 615008
- Company Name
- B BRAUN INTERVENTIONAL SYSTEMS, INC
- Labeler DUNS
- 784259751
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-08-09
- Public Version
- 5
- Public Version Date
- 2022-11-02
- Public Version Status
- Update
- Public Device Record Key
- 13907258-4866-4d32-b20d-f14eeb69a300
- Distribution End Date
- 2021-03-11
Device Description
MULTITRACK ANGIO CATH 2.5F,80"
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DQO | CATHETER, INTRAVASCULAR, DIAGNOSTIC | Cardiovascular | 870.1200 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 10688 | Angiographic catheter, single-use | A thin, flexible tube designed to inject a contrast medium into select blood vessels of the cerebral, visceral, or peripheral vasculature during an angiographic procedure in order to facilitate the clear visualization of the vascular system of a targeted organ or area of the body. It is introduced percutaneously, has a radiopaque marker(s) for positioning, and may include disposable devices dedicated to catheter introduction/function [e.g., sheath(s)]. It may also be used for simultaneous pressure measurements to determine the transvalvular, intravascular, and intraventricular pressure gradients. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04046964312854 | GS1 |
Customer Contacts
- Phone
- +1(877)836-2228
- [email protected]
Storage Conditions
- Type
- Special Storage Condition, Specify
- Type
- Special Storage Condition, Specify
- Special Conditions
- ROOM TEMP AWAY FROM SUNLIGHT