FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Micro-Access Elite®
DI: 04046964309809
·
Model: 613340
·
B BRAUN INTERVENTIONAL SYSTEMS, INC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Micro-Access Elite®
- Primary DI
- 04046964309809
- Version / Model
- 613340
- Catalog Number
- 613340
- Company Name
- B BRAUN INTERVENTIONAL SYSTEMS, INC
- Labeler DUNS
- 784259751
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-08-09
- Public Version
- 6
- Public Version Date
- 2022-11-02
- Public Version Status
- Update
- Public Device Record Key
- 36f4a843-8012-4a68-96ff-d29f10a507ca
- Distribution End Date
- 2021-03-11
Device Description
4FX5.5CM MEH-018X40 NT/AU GW-7CM NDL
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DYB | INTRODUCER, CATHETER | Cardiovascular | 870.1340 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 58865 | Vascular catheter introduction set, nonimplantable | A collection of sterile, nonimplantable, invasive devices intended to provide percutaneous vascular access to enable introduction of a catheter (not included) into the vascular system. It includes a non-steerable introducer sheath with an inner obturator/dilator, and typically an additional access device(s) [e.g., guidewire, introducer needle, syringe, additional dilators] which may include a haemostatic valve to control blood loss, usually to enable arterial access. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 04046964309809 | GS1 |
Customer Contacts
- Phone
- +1(877)836-2228
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K043525 | 000 |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Type
- Special Storage Condition, Specify
- Special Conditions
- STORE AT ROOM TEMPERATURE.