ART-Plan
Basic Information
- Brand Name
- ART-Plan
- Primary DI
- 03770019940020
- Version / Model
- V3.X
- Company Name
- THERAPANACEA
- Labeler DUNS
- 269366925
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2025-12-10
- Public Version
- 1
- Public Version Date
- 2025-12-18
- Public Version Status
- New
- Public Device Record Key
- 3ea08316-432d-40f3-96ce-2da822bf1986
Device Description
The current version of the medical device includes the Annotate, SmartFuse, SmartPlan and AdaptBox modules. The Annotate module allow the contouring of regions of interest. The module Smartplan allows the creation of an automatic treatment plan based on a planning CT and a RTSS The Smartfuse module is also providing the possibility to do a fusion of images from different modalities. The Adaptbox module is a helping tool to decide if a replanning is necessary. For this purpose, the module allows the user to generate a synthetic-CT from a CBCT image, to auto-delineate regions of interest on the synthetic-CT, to compute the dose on both planning CT and synthetic-CT and then define if there is a need for replanning by comparing volume and dose metrics computed on both images and over the course of the treatment. Those metrics are defined by the user. This version also contains an administration module, that allows the user to manage data and rights.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| QKB | Radiological Image Processing Software For Radiation Therapy | Radiology | 892.2050 | 2 |
| MUJ | System, Planning, Radiation Therapy Treatment | Radiology | 892.5050 | 2 |
| LLZ | System, Image Processing, Radiological | Radiology | 892.2050 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 40887 | Radiation therapy software | An application software program intended to facilitate/support the delivery of therapeutic radiation by enabling computer-assisted functionality in one or more of the following areas: treatment planning, simulation, record/verify, beam block CAD/CAM, quality assurance, and patient positioning. Some types may be combined with specific hardware or firmware accessories or configurations in order to function as intended. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 03770019940020 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K242822 | 000 |