FDA UDI
In Commercial Distribution
🇺🇸 United States
Navigation set SPX1, Targeting Needle SPX1, Trocar Tip - 11G, 125 mm
DI: 03701311501077
·
Model: A01029
·
ECENTIAL ROBOTICS
Product Codes
1
GMDN Terms
3
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Navigation set SPX1, Targeting Needle SPX1, Trocar Tip - 11G, 125 mm
- Primary DI
- 03701311501077
- Version / Model
- A01029
- Company Name
- ECENTIAL ROBOTICS
- Labeler DUNS
- 261610964
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2023-09-04
- Public Version
- 3
- Public Version Date
- 2023-11-03
- Public Version Status
- Update
- Public Device Record Key
- 43b7418d-1c0b-45d7-b010-001b604f7786
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| OLO | Orthopedic Stereotaxic Instrument | Neurology | 882.4560 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 45170 | Stereotactic surgery system probe, single-use | A slender, rod-like, hand-held manual surgical instrument intended for use during image-guided surgery (e.g., neurosurgical or orthopaedic surgery procedures) to accurately position implantable devices (e.g., shunts), or to correlate the position of its tip with that of a targeted tissue of interest in a patient so the tissue area is precisely identified with respect to diagnostic images stored in the stereotactic surgery system. It is made of metal. This is a single-use device. | No | Active |
| 60478 | Bone access cannula | A sterile, sharp, hollow tubular metal instrument designed for percutaneous insertion to provide access to any bone of the body for a bone biopsy needle or guidewire, or for a bone marrow aspiration technique, or for inserting therapeutic materials, including bone cements. It is typically inserted using a stylet under imaging [e.g., fluoroscopic, ultrasonic, computed tomography (CT)] control and has a proximal plastic handgrip to apply manual pressure and twist. This is a single-use device. | No | Active |
| 65388 | Surgical optical-tracking spatial marker, single-use | A non-powered, noninvasive component of a surgical navigation and/or device tracking system (e.g., computer-assisted surgical ultrasound system, surgical microscope) intended for preoperative and/or intraoperative use to function as an optical reference to enable spatial registration/tracking of the position/movement/size of a patient, another marker and/or surgical instrument (e.g., stereotactic surgery probe). It may be attached to the patient, another marker or surgical instrument, and may contain features (e.g., reflective spheres, contrast patterns) detectable by a tracking camera. Procedural supportive devices (e.g., drapes) may be included with the device. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 03701311501077 | GS1 |
Customer Contacts
- Phone
- +33458005520
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K221028 | 000 |