FDA UDI
Not in Commercial Distribution
🇺🇸 United States
hipEOS
DI: 03700757200520
·
Model: 2.5
·
ONEFIT MEDICAL
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- hipEOS
- Primary DI
- 03700757200520
- Version / Model
- 2.5
- Company Name
- ONEFIT MEDICAL
- Labeler DUNS
- 263373588
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-26
- Public Version
- 4
- Public Version Date
- 2021-02-02
- Public Version Status
- Update
- Public Device Record Key
- ce12f059-96ca-4921-93ea-cf334143ecb9
- Distribution End Date
- 2019-10-21
Device Description
hipEOS allows surgeons to perform pre-operative surgical planning for hip replacement. The program features an extensive regularly updated library of digital 3D models of implants form leading implant manufacturers. It allows the overlay of the 3D/2D implant models on the radiological images and on the 3D reconstruction and permits the selection of appropriate size and position of implant.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LLZ | System, Image Processing, Radiological | Radiology | 892.2050 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46470 | Orthopaedic/craniofacial implantation planning software | A software program intended to add specific computer-assisted display, processing, and/or analysis capabilities to prepare for the implantation of an orthopaedic and/or craniomaxillofacial (CMF) prosthesis. Using digitized x-rays or imported computed tomography (CT) images, it provides implant-site anatomical images, and using computerized files representing implant patterns, provides the surgeon with images that help determine the appropriate size and placement of the implant. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 03700757200520 | GS1 |
Customer Contacts
- Phone
- +381252427
- [email protected]