FDA UDI
In Commercial Distribution
🇺🇸 United States
Extraction Kit
DI: 03665039005630
·
Model: B-4815
·
PRINCE MEDICAL
Product Codes
2
GMDN Terms
2
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Extraction Kit
- Primary DI
- 03665039005630
- Version / Model
- B-4815
- Catalog Number
- B-4815
- Company Name
- PRINCE MEDICAL
- Labeler DUNS
- 569442924
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2024-01-30
- Public Version
- 1
- Public Version Date
- 2024-02-07
- Public Version Status
- New
- Public Device Record Key
- 8901a1c8-6226-41fa-a434-bbd4338c2a41
Device Description
Endoline PUNC and Endoline VIPER
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GAD | Retractor | General, Plastic Surgery | 878.4800 | 1 |
| LTI | Implant, Intragastric For Morbid Obesity | Unknown | 3 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61507 | Gastrointestinal needle catheter | A sterile, flexible tube with a retractable needle at the distal end intended for puncturing an inflated balloon within the gastrointestinal tract (e.g., appetite-suppression gastric balloon) to enable its removal. It is introduced through an endoscope and the needle action controlled by a handle at the proximal end. This is a single-use device. | No | Active |
| 33199 | Flexible endoscopic tissue manipulation forceps, single-use | A flexible, hand-held manual surgical instrument designed to be introduced through the working channel of an endoscope to grasp tissue (typically atraumatically), or additionally foreign bodies. It has proximal controls (e.g., scissors-like handles), a flexible long slender shaft, and distal grasping jaws; it is not an electrosurgical device and is not dedicated to biopsy. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 03665039005630 | GS1 |