Focal One
Basic Information
- Brand Name
- Focal One
- Primary DI
- 03661690000052
- Version / Model
- TMS 239320
- Company Name
- EDAP-TMS FRANCE
- Labeler DUNS
- 383113362
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-06-11
- Public Version
- 3
- Public Version Date
- 2020-07-30
- Public Version Status
- Update
- Public Device Record Key
- f1211e35-f102-4f1b-a767-1201fda7c4a0
Device Description
The device is a computer-controlled medical device intended to provide High Intensity Focused Ultrasound (also referred to as HIFU) to ablate prostate tissue. The Focal One system consists of the following main sub-assemblies: Focal One Control Module, Dynamic Focal Probe, and consumable Focalpak. HIFU is a unique process of delivering a large amount of heat energy to a confined space in a highly controlled manner. This energy heats the tissue to ablation levels while minimizing the effect on surrounding structures. The ultrasound energy is delivered via an endorectal probe, which includes an imaging system. The ultrasound waves propagate through the rectal wall and are focused on a portion of the prostate, generating intense heat and causing the ablation of tissue within the targeted area. The process is then repeated in a stepwise fashion to destroy the targeted tissues within the prostate. The apex, sphincter and rectum are preserved while prostate tissues are ablated.Imported diagnostic data can be fused with the real time ultrasound image in order to facilitate the targeting of the ablation volume.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| PLP | High Intensity Ultrasound System For Prostate Tissue Ablation | Gastroenterology, Urology | 876.4340 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 11248 | Physical therapy ultrasound system | An assembly of devices designed to produce and deliver ultrasonic waves that penetrate tissues and produce both thermal and nonthermal (e.g., mechanical and cavitation) effects to treat pain (e.g., muscle, tendon, joint) and as an aid in the healing of soft-tissue injuries (e.g., ulcerations, bursitis). It typically consists of a radio-frequency (RF) generator (frequencies from one to three megahertz are typical), a cable that transmits the RF energy to the applicator, and an applicator including a piezoelectric transducer that applies the ultrasonic energy to the patient's tissues through the skin. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 03661690000052 | GS1 |
Customer Contacts
- Phone
- +33763346399
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K172721 | 000 |