FDA UDI
Not in Commercial Distribution
🇺🇸 United States
EMPERION
DI: 03596010561572
·
Model: 71291652
·
Smith & Nephew, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- EMPERION
- Primary DI
- 03596010561572
- Version / Model
- 71291652
- Catalog Number
- 71291652
- Company Name
- Smith & Nephew, Inc.
- Labeler DUNS
- 045483575
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-08-29
- Public Version
- 5
- Public Version Date
- 2023-09-07
- Public Version Status
- Update
- Public Device Record Key
- 2045bef1-a096-4632-ace5-04ca87cf262b
- Distribution End Date
- 2018-04-04
Device Description
EMPERION 11 SLEEVE SMALL CONE 2 SPOUT
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MEH | Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate | Orthopedic | 888.3353 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 33581 | Coated hip femur prosthesis, modular | A sterile implantable principal component of a total hip prosthesis (femoral component) designed to replace the femoral head and neck; the device is composed of two or more separate pieces (e.g., head, neck, and stem) designed to be joined and is coated with a material (e.g., porous materials, hydroxyapatite) intended to improve fixation and stability by promoting bone ingrowth. The device may be made of metal and/or ceramic materials. Fixation devices for implantation (e.g., screws and bolts) may be included and implantation may be performed with or without bone cement. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 03596010561572 | GS1 |
Customer Contacts
- Phone
- +1(800)238-7538
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K042127 | 000 |