FDA UDI
In Commercial Distribution
🇺🇸 United States
Spiration Valve System
DI: 00896506002286
·
Model: SVS-V5-00
·
Gyrus Acmi, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Spiration Valve System
- Primary DI
- 00896506002286
- Version / Model
- SVS-V5-00
- Company Name
- Gyrus Acmi, Inc.
- Labeler DUNS
- 117521967
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2019-03-29
- Public Version
- 2
- Public Version Date
- 2021-03-04
- Public Version Status
- Update
- Public Device Record Key
- c68e5786-a3d6-4563-b2bb-b5e8eb241d4e
Device Description
Valve in Cartridge , 5mm
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| NJK | Valve, Pulmonary | Unknown | 3 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47613 | Endobronchial valve | A sterile, non-surgical implantable device designed to be placed in a bronchial lumen to control bronchial airflow and improve health status, typically in a patient with emphysema and/or to reduce bronchial air leaks. It consists of a one-way valve that includes an expanding frame (e.g., Nitinol) with features to prevent migration after implantation, and a plastic membrane. It is intended to limit airflow distal to the valve while allowing mucus and air movement proximally. This results in the valve redirecting air to healthy portions of the lungs and/or venting lung segments to achieve pneumoreduction. The valve may remain permanently implanted or removed when medical indicated. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00896506002286 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| P180007 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Outer Diameter | 5 | Millimeter |