FDA UDI
In Commercial Distribution
🇺🇸 United States
Arthrex®
DI: 00888867107014
·
Model: AR-513-14100
·
ARTHREX, INC.
Product Codes
3
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Arthrex®
- Primary DI
- 00888867107014
- Version / Model
- AR-513-14100
- Catalog Number
- AR-513-14100
- Company Name
- ARTHREX, INC.
- Labeler DUNS
- 131747628
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-02-15
- Public Version
- 7
- Public Version Date
- 2024-01-09
- Public Version Status
- Update
- Public Device Record Key
- f630d44d-98dc-4cfc-988e-fde9d08fe49d
Device Description
IBAL TKA TIB STEM,CM,14MM DX 100MM L
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MBH | PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER | Orthopedic | 888.3565 | 2 |
| KRR | PROSTHESIS, KNEE, PATELLO/FEMORAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER | Orthopedic | 888.3540 | 2 |
| HSX | PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER | Orthopedic | 888.3520 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 32832 | Uncoated knee tibia prosthesis, metallic | An implantable device designed to replace the tibial condyles (tibial component) during primary bicondylar replacement of the knee joint, femoral bone resection, or to replace a dysfunctional knee prosthesis (revision); it is made of metal [e.g., cobalt-chrome (Co-Cr), cobalt-chrome-molybdenum (Co-Cr-Mo), titanium (Ti)] and is not coated with a material intended to improve fixation and stability by promoting bone ingrowth. The device is designed to articulate with an insert and/or the femoral prosthetic component of the knee joint and its implantation is intended to be performed with bone cement. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00888867107014 | GS1 | ||||
| Secondary | M150AR513141001 | HIBCC |
Customer Contacts
- Phone
- +1(800)934-4404
- [email protected]