FDA UDI
In Commercial Distribution
🇺🇸 United States
MEMORIAL SLOAN KETTERING PRI SET
DI: 00886333671953
·
Model: 687195
·
ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- MEMORIAL SLOAN KETTERING PRI SET
- Primary DI
- 00886333671953
- Version / Model
- 687195
- Catalog Number
- 687195
- Company Name
- ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
- Labeler DUNS
- 595138793
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-22
- Public Version
- 2
- Public Version Date
- 2018-03-29
- Public Version Status
- Update
- Public Device Record Key
- 3571e1f1-d70b-4762-aac2-e6140456ce10
Device Description
a 2-way Adset of tube lengths 60" with 1 line connected to a 3cc transducer and pressure tubing of lengths 72" and 12" and stopcocks. The other line is left open for other connection. It includes a separately packed 3xmale, 1x Female protective caps and a Colour Set
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DXN | System, Measurement, Blood-Pressure, Non-Invasive | Cardiovascular | 870.1130 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35529 | Invasive blood pressure monitoring tubing set | A collection of devices that includes the necessary tubing and other items, e.g., connectors, stopcock(s), clamps and filters, used as an external connection for invasive blood pressure measurement. This set will interface, either directly or from an intermediate stopcock, between the applied invasive catheter and the measuring transducer. It will have physical characteristics appropriate for preserving, to the extent possible, the waveform and fidelity of the measured pressure. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 50886333671958 | GS1 | Tyvek Bag | 20 | In Commercial Distribution | |
| Primary | 00886333671953 | GS1 |
Customer Contacts
- Phone
- 1.800.927.4669
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | 3cc transducer |