FDA UDI
In Commercial Distribution
🇺🇸 United States
Silicone PIP
DI: 00885556858523
·
Model: SPIP-520-3-WW
·
Smith & Nephew, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Silicone PIP
- Primary DI
- 00885556858523
- Version / Model
- SPIP-520-3-WW
- Catalog Number
- SPIP-520-3-WW
- Company Name
- Smith & Nephew, Inc.
- Labeler DUNS
- 045483575
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2022-12-22
- Public Version
- 3
- Public Version Date
- 2024-02-08
- Public Version Status
- Update
- Public Device Record Key
- ecc9ca8c-0956-40b3-82a5-f76bde49fdec
Device Description
Silicone PIP SZ 3
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| KYJ | Prosthesis, finger, constrained, polymer | Orthopedic | 888.3230 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 60459 | Proximal interphalangeal joint prosthesis, modular | A sterile, implantable artificial substitute for the proximal interphalangeal (PIP) joint(s) of the hand (finger) which typically has been damaged by rheumatoid, degenerative, or traumatic arthritis. The device typically consists of proximal and distal metal (e.g., titanium) stems, which may be coated with a material (e.g., hydroxyapatite) intended to improve fixation and stability by promoting bone ingrowth, for insertion into the prepared phalanges of the joint. The stems may have articulating surfaces or there may be separate metal [e.g., cobalt-chrome (Co-Cr)] and/or plastic ( e.g., polyethylene) articulating surface components. Dedicated tools for implantation may be included. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00885556858523 | GS1 |
Customer Contacts
- Phone
- +1(800)238-7538
- [email protected]