FDA UDI
In Commercial Distribution
🇺🇸 United States
BioMotion Cannulated 1st MPJ Hemi System
DI: 00885556821701
·
Model: HM1900
·
Smith & Nephew, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- BioMotion Cannulated 1st MPJ Hemi System
- Primary DI
- 00885556821701
- Version / Model
- HM1900
- Catalog Number
- HM1900
- Company Name
- Smith & Nephew, Inc.
- Labeler DUNS
- 045483575
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2022-12-21
- Public Version
- 2
- Public Version Date
- 2023-09-07
- Public Version Status
- Update
- Public Device Record Key
- 7213cdd8-f12b-4d3b-b77e-d411554380f5
Device Description
CANNULATED HEMI IMPLANT MEDIUM (19MM)
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| KWD | PROSTHESIS, TOE, HEMI-, PHALANGEAL | Orthopedic | 888.3730 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 33720 | Wrist ulna-head prosthesis | A sterile implantable device designed to replace the distal ulnar head of the radio-ulnar joint following ulnar head resection typically due to arthritis, post-traumatic disabilities (pain, weakness, instability), or failed alternative treatment. It may be a one-piece or modular device made of metal [e.g., cobalt-chrome (Co-Cr), titanium (Ti), stainless steel] and/or polyethylene (PE). Fixation devices for implantation (e.g., screws) may be included and implantation may be performed with or without bone cement. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00885556821701 | GS1 |
Customer Contacts
- Phone
- +1(800)238-7538
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K083469 | 000 |