FDA UDI
In Commercial Distribution
🇺🇸 United States
SO2 Module
DI: 00884838020931
·
Model: Intravascular Oxygen Saturation Module
·
Philips Medizin Systeme Böblingen GmbH
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- SO2 Module
- Primary DI
- 00884838020931
- Version / Model
- Intravascular Oxygen Saturation Module
- Catalog Number
- 865124
- Company Name
- Philips Medizin Systeme Böblingen GmbH
- Labeler DUNS
- 314101143
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-10-12
- Public Version
- 8
- Public Version Date
- 2023-05-05
- Public Version Status
- Update
- Public Device Record Key
- db9499fa-6830-4e17-9506-376178ec487f
Device Description
Intravascular Oxygen Saturation Module for use with IntelliVue Patient Monitors. The Module allows continuous measurement of mixed venous oxygen saturation (SvO2) and central venous oxygen saturation (ScvO2).
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DQA | Oximeter | Cardiovascular | 870.2700 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 15200 | Intracardiac oximeter | A mains electricity (AC-powered) photoelectric device designed to transmit radiation at a known wavelength(s) through blood to measure the concentration of oxygen, or dye, within the heart based on the amount of reflected or scattered radiation. It is typically used in conjunction with a fibreoptic oximeter catheter (e.g., a Swan-Ganz catheter) that is introduced via a vein in the groin or neck to measure mixed venous oxygen saturation (SvO2) or evaluate intracardiac shunts. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00884838020931 | GS1 |
Customer Contacts
- Phone
- +1(999)999-9999
- [email protected]
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- -20 – 60 Degrees Celsius
- Type
- Storage Environment Temperature
- Temperature Range
- -4 – 140 Degrees Fahrenheit
- Type
- Storage Environment Atmospheric Pressure
- Temperature Range
- 57 – 106 KiloPascal
- Type
- Storage Environment Humidity
- Temperature Range
- 15 – 90 Percent (%) Relative Humidity