FDA UDI
Not in Commercial Distribution
🇺🇸 United States
microTargeting™ Single Procedure Kit
DI: 00873263001332
·
Model: KTF1001-00133
·
FHC, INC.
Product Codes
2
GMDN Terms
3
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- microTargeting™ Single Procedure Kit
- Primary DI
- 00873263001332
- Version / Model
- KTF1001-00133
- Catalog Number
- KTF1001
- Company Name
- FHC, INC.
- Labeler DUNS
- 108179458
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-08-22
- Public Version
- 9
- Public Version Date
- 2023-01-10
- Public Version Status
- Update
- Public Device Record Key
- 872889bc-c07e-48ad-ac09-a52e8629acce
- Distribution End Date
- 2023-01-10
Device Description
microTargeting Single Procedure Kit, with microElectrode, tubes, sterile drape sleeve and cable. Contains: IT(BP2): Insertion Tube. 2x MTDWLN(BP)(BP7): microTargeting Electrode. PT(BP2): Protective Tube. Sterile Drape Sleeve for microTargeting motor FC1020 Electrode Lead Individual Specifications: IT(BP2) - 183mm tube length, 1.829mm OD, 1.6mm ID, 184mm stylet (not including collar). MTDWLN(BP)(BP7) - 271.4mm electrode length, 10mm differential, 256.4mm protective tube length, 0.77mm OD. 1Meg DZAP(L) PT(PB2) - 181mm tube length, 1.47mm OD, 0.99mm ID OD: 0.77mm
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Ethylene Oxide
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HAW | Neurological stereotaxic Instrument | Neurology | 882.4560 | 2 |
| GZL | ELECTRODE, DEPTH | Neurology | 882.1330 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47783 | Patient surgical drape, single-use | A noninvasive sheet designed to cover a portion of a patient’s anatomy during a surgical procedure to function as a barrier to cross contamination (e.g., isolate a site of surgical incision, protect non-operative anatomy). It is not designed with specific heat-reflective or laser resistant materials. It is available in a variety of designs (e.g., flat sheet with or without an access hole, leg tube or an adhesive film sheet otherwise known as an incise drape). This is a single-use device. | No | Active |
| 61964 | Intracerebral cannula, implantable | A sterile, implantable tube intended to be surgically placed in a specific area of the brain (e.g., basal ganglia) to position a deep brain electrical stimulation lead/electrode, using a stereotactic surgery system, and to function as a guide for subsequent and regular placement and/or removal of the lead/electrode. It is made of synthetic polymer materials (e.g., polyurethane) and may include a stylet/trocar blade. | Yes | Active |
| 32556 | Depth electrode | An electrical conductor intended to be temporarily placed (< 30 days) beneath the surface of the brain to stimulate the brain or to record the brain's electrical activity (with more precise localization than a scalp electrode). It is typically a fine, flexible plastic device attached to wires that carry currents from deep and superficial brain structures. The wires are connected to recording, monitoring, or stimulation/response devices [e.g., electroencephalograph (EEG), evoked-potential recorder, stimulator]. The implant is particularly helpful in determining site of origin in temporal and frontal lobe epilepsy. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00873263001332 | GS1 |
Customer Contacts
- Phone
- +1(800)326-2905
- [email protected]
Premarket Submissions
Storage Conditions
- Type
- Handling Environment Humidity
- Temperature Range
- 0 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- 0 – 40 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 0 – 95 Percent (%) Relative Humidity