FDA UDI
Not in Commercial Distribution
🇺🇸 United States
microTargeting™ Insertion Tube Set
DI: 00873263001301
·
Model: FC1011-00130
·
FHC, INC.
Product Codes
1
GMDN Terms
2
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- microTargeting™ Insertion Tube Set
- Primary DI
- 00873263001301
- Version / Model
- FC1011-00130
- Catalog Number
- FC1011
- Company Name
- FHC, INC.
- Labeler DUNS
- 108179458
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-08-22
- Public Version
- 5
- Public Version Date
- 2023-01-10
- Public Version Status
- Update
- Public Device Record Key
- 539e3971-75cd-4933-a77f-fb3c0afec20d
- Distribution End Date
- 2023-01-10
Device Description
microTargeting Single Electrode Insertion Tube Set Contains: 66-IT-01 (One IT(BP2), One PT(BP2), One Spacer Cleaning Tool, One Electrode Carrier, One Shielded Electrode Carrier) depth when used with frame and Star or mT Drive is 40mm above target Individual Specifications: IT(BP2): Length=183mm, OD=1.83mm, ID=1.60mm PT(BP2): Length=181mm, OD=1.47mm, ID=0.99mm
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- ["Ethylene Oxide", "Moist Heat or Steam Sterilization"]
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HAW | Neurological stereotaxic Instrument | Neurology | 882.4560 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61964 | Intracerebral cannula, implantable | A sterile, implantable tube intended to be surgically placed in a specific area of the brain (e.g., basal ganglia) to position a deep brain electrical stimulation lead/electrode, using a stereotactic surgery system, and to function as a guide for subsequent and regular placement and/or removal of the lead/electrode. It is made of synthetic polymer materials (e.g., polyurethane) and may include a stylet/trocar blade. | Yes | Active |
| 46863 | Neurosurgical micro targeting drive | A calibrated guide mechanism used by a surgeon to manually operate a Z-axis positioner which allows extremely accurate placement of a single or multiple microelectrodes, stimulation electrodes, probes, instruments, or implantable devices, along a chosen track during neurosurgery on the brain. It is intended to be used with a neurosurgical stereotactic system. It typically consists of a metal, graduated frame along which an instrument holder traverses (e.g., approximately 50 mm) by adjustment of a graduated knob that revolves a fine pitched lead screw (e.g., one revolution of the knob will advance the drive by 1 mm). Some types can have an electrical motor attached for motorized drive. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00873263001301 | GS1 |
Customer Contacts
- Phone
- +1(800)326-2905
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K011775 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 40 | Millimeter |
Storage Conditions
- Type
- Handling Environment Humidity
- Temperature Range
- 0 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- 0 – 40 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 0 – 95 Percent (%) Relative Humidity