FDA UDI
In Commercial Distribution
🇺🇸 United States
Oxlife Freedom POC
DI: 00869694000129
·
Model: 301-0003V
·
O2 CONCEPTS, LLC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Oxlife Freedom POC
- Primary DI
- 00869694000129
- Version / Model
- 301-0003V
- Company Name
- O2 CONCEPTS, LLC
- Labeler DUNS
- 034756852
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2019-04-15
- Public Version
- 2
- Public Version Date
- 2020-04-20
- Public Version Status
- Update
- Public Device Record Key
- a9ea79ac-7783-4a6f-9e42-35c2ee5b8a8e
Device Description
The O2 Concepts Oxlife Freedom is indicated on a prescription basis for the administration of supplemental oxygen. It is not intended for life support, nor does it provide any patient monitoring capabilities.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| CAW | Generator, Oxygen, Portable | Anesthesiology | 868.5440 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 31321 | Mobile/portable oxygen concentrator | A mobile/portable mains electricity (AC-powered) device designed to concentrate oxygen (O2) from ambient air and deliver the concentrated O2, typically through an attached nasal cannula, to a patient requiring oxygen therapy. It processes the air through an internal filtration system, e.g., a molecular sieve (zeolite granules or membranes), having a large total surface area to separate nitrogen (N2) from the air. It typically consists of an air compressor, filters, dual chambers, a reservoir and controls. The O2 concentration is variable depending on the flow rate utilized. It is used in a home, institution, or a vehicle and typically has internal batteries for transportable use. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00869694000129 | GS1 |
Customer Contacts
- Phone
- 877-867-4008
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K182454 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- -4 – 140 Degrees Fahrenheit
- Type
- Storage Environment Humidity
- Temperature Range
- 0 – 95 Percent (%) Relative Humidity