FDA UDI
In Commercial Distribution
🇺🇸 United States
statMAP
DI: 00860498002616
·
Model: Re-manufactured
·
RAMSEY MEDICAL, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- statMAP
- Primary DI
- 00860498002616
- Version / Model
- Re-manufactured
- Catalog Number
- 7200-9999
- Company Name
- RAMSEY MEDICAL, INC.
- Labeler DUNS
- 075865678
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2019-02-26
- Public Version
- 2
- Public Version Date
- 2019-11-08
- Public Version Status
- Update
- Public Device Record Key
- b053f9c1-2b20-4831-aeee-4e2599dba4f3
Device Description
Re-manufactured electronic, hand-held, battery operated blood pressure measurement device.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DXN | System, Measurement, Blood-Pressure, Non-Invasive | Cardiovascular | 870.1130 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47489 | Manual-inflation electronic sphygmomanometer, portable | An electrically-powered device designed to noninvasively measure blood pressure using a manually-inflated cuff that typically fits around a limb (arm or thigh). It typically displays current heart rate and mean arterial pressure in addition to systolic and diastolic blood pressures; it may have memory to store blood pressure values and may sound an alarm if blood pressure exceeds pre-set limits. This device is designed to be portable (e.g., hand-held or carried in a pouch) and is often used for emergency services or home blood pressure monitoring. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00860498002616 | GS1 |
Customer Contacts
- Phone
- (800) 231-6370
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K072109 | 000 |
Storage Conditions
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 75 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- -4 – 131 Degrees Fahrenheit