FDA UDI
In Commercial Distribution
🇺🇸 United States
Zap-X MV Imager
DI: 00860183001535
·
Model: 300153
·
ZAP SURGICAL SYSTEMS, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Zap-X MV Imager
- Primary DI
- 00860183001535
- Version / Model
- 300153
- Company Name
- ZAP SURGICAL SYSTEMS, INC.
- Labeler DUNS
- 082344400
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-08-29
- Public Version
- 1
- Public Version Date
- 2018-10-01
- Public Version Status
- New
- Public Device Record Key
- 00dda49e-ac34-4ffe-94dc-17d904d9591c
Device Description
The Zap-X MV Imager is designed for use with the Zap-X Radiosurgery System (“Zap-X System”) which is a computer-controlled system for performing non-invasive stereotactic radiosurgery that is self-shielded for ionizing radiation.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| IYE | Accelerator, Linear, Medical | Radiology | 892.5050 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 18054 | Stereotactic radiosurgery/radiation therapy linear accelerator system | A stationary assembly of computer-based devices designed to produce high-energy electrons to yield high-energy x-rays used to perform stereotactic radiosurgery (SRS) to treat brain, neck, or spinal cord tumours, and/or to perform stereotactic body radiation therapy (SBRT). It consists of a linear accelerator with a moveable/rotating gantry, collimators, patient table, and an operator's console. A metal head frame attached to the patient's skull may be used for precise radiation beam targeting using fiducial references; the system may include CBCT-based image-guided radiation therapy (IGRT), 3-D imaging, and record/verify functionalities to track target location during treatment. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00860183001535 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K171804 | 000 |