FDA UDI In Commercial Distribution 🇺🇸 United States

Ampa One System

DI: 00860011991212 · Model: AMPA-001 · Neuromodulatory Devices & Applications LLC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1

Let the assistant research this device

The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.

Free to try · every answer cites its records

Basic Information

Brand Name
Ampa One System
Primary DI
00860011991212
Version / Model
AMPA-001
Company Name
Neuromodulatory Devices & Applications LLC
Labeler DUNS
118996575
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2025-07-28
Public Version
1
Public Version Date
2025-08-05
Public Version Status
New
Public Device Record Key
c1ca89c1-895c-4a3e-acae-2645d2f4bda8

Device Description

The Ampa One System is a computerized, electromechanical medical device that produces and delivers non-invasive, magnetic fields to induce electrical currents in brain tissues to target specific regions of the cerebral cortex. The system contains two different coils for targeting different regions of the brain. The L Coil is designed to target the left dorsolateral prefrontal cortex (DLPFC). The M Coil is designed to target the bilateral prefrontal cortex (DMPFC). Both coils are used within the Ampa One System to treat Major Depressive Disorder (MDD) in adult patients who have failed to receive satisfactory improvement from prior antidepressant medication in the current episode. Transcranial magnetic stimulation (TMS) is a non-invasive technique for stimulating brain and neural tissue. The principle of magnetic stimulation is implicit in Faraday's law. The pulses of current are generated with a circuit containing a capacitor connected to the stimulating coil. With the capacitor charged to a certain level, the conducting state will cause the discharging of the capacitor through the coil. A magnetic field is generated proportional to this current. The rapid change in the magnetic field induces a current in conducting materials e.g. the body tissue. If the current induced in the human body is of sufficient amplitude and duration, it will excite neurons.

Device Characteristics

Single Use
No
Prescription Use (Rx)
Yes
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
No
Has Serial Number
No
Has Lot/Batch Number
Yes
Has Manufacturing Date
Yes
Has Expiration Date
No
Has Donation ID
No

Sterilization

Is Sterile
No
Sterilization Prior Use
No

Product Codes

Code Name
OBP Transcranial Magnetic Stimulator

GMDN Terms

Code Name
61124 Magnetic neural stimulation system

Identifiers

Type ID
Primary 00860011991212

Customer Contacts

Phone
2488257429

Premarket Submissions

Submission Number Supplement Number
K251210 000