FDA UDI
In Commercial Distribution
🇺🇸 United States
Aventus Thrombectomy System
DI: 00860009303447
·
Model: AV24MAX-92-M
·
Inquis Medical, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Aventus Thrombectomy System
- Primary DI
- 00860009303447
- Version / Model
- AV24MAX-92-M
- Company Name
- Inquis Medical, Inc.
- Labeler DUNS
- 117606791
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2025-08-20
- Public Version
- 1
- Public Version Date
- 2025-08-28
- Public Version Status
- New
- Public Device Record Key
- 4456e00e-0137-4121-bc68-0b909f2f85c5
Device Description
The Aventus Thrombectomy System is a catheter-based manual aspiration system designed for minimally invasive removal of emboli and thrombi from pulmonary arteries, the peripheral vasculature and/or infusing fluids.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Ethylene Oxide
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| QEW | Peripheral Mechanical Thrombectomy With Aspiration | Cardiovascular | 870.5150 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 58173 | Thrombectomy suction catheter | A flexible or semi-flexible tube designed for the percutaneous, transluminal disruption and removal of clotted blood (i.e., a thrombus or thromboembolus) or other formed elements causing vascular obstruction in native/stented blood vessels, native/synthetic bypass grafts, and/or haemodialysis access grafts, through suction (aspiration) in conjunction with a syringe or dedicated suction pump system (pump not included). It may additionally be intended for infusion of fluids and/or used as a guide-catheter to facilitate introduction of a thrombectomy wire-net (not included) to remove residual thrombus. Collection containers may be included with the catheter. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00860009303447 | GS1 |