Us2.v1
Basic Information
- Brand Name
- Us2.v1
- Primary DI
- 00860005876808
- Version / Model
- 1
- Company Name
- EKO.AI PTE. LTD.
- Labeler DUNS
- 659454378
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2022-11-16
- Public Version
- 3
- Public Version Date
- 2023-12-04
- Public Version Status
- Update
- Public Device Record Key
- 3f05c89f-05be-4944-bd3c-f8e60aff5e33
Device Description
Us2.v1 is a fully automated software platform that processes, analyses and makes measurements on acquired transthoracic cardiac ultrasound images, automatically producing a full report with measurements of several key cardiac structural and functional parameters. The data produced by this software is intended to be used to support qualified cardiologists or licensed primary care providers for clinical decision-making. Us2.v1 is indicated for use in adult patients. Us2.v1 has not been validated for the assessment of congenital heart disease, valve disease, pericardial disease and/or intra-cardiac lesions (e.g tumors, thrombi). Please note the following limitations: - Poor image capture will lead to poor annotations and subsequent measurements. Multiple image quality algorithms are used to filter out images of poor quality. - Our software complements good patient care and does not exempt the user from the responsibility to provide supervision, clinically review the patient, and make appropriate clinical decisions. - If no gender is present, female referenced guideline values will be used for conclusions. - If Body Surface Area (BSA) is not present, indexed values cannot be provided. - During image acquisition, inappropriate use of the echo machine, use of non-cardiac ultrasound probes, use of suboptimal settings (e.g. gain, contrast, depth), or lack of electrocardiogram capture may lead to lower accuracy of the software.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| QIH | Automated Radiological Image Processing Software | Radiology | 892.2050 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 57812 | Radiology DICOM image processing application software | A software application intended to facilitate management, distribution, and/or viewing of radiological digital imaging and communications in medicine (DICOM) image data; it is not intended for pathological image interpretation (i.e., not intended to detect and localize suspected abnormalities). It may be intended to facilitate image management (e.g., viewing, communication, printing, recording/disc burning) and/or image quality manipulation and quantification (e.g., non-interpretive graphical overlays). | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00860005876808 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K210791 | 000 |