FDA UDI
In Commercial Distribution
🇺🇸 United States
AuraGen Aesthetics
DI: 00860003492703
·
Model: 100358
·
Auragen Aesthetics LLC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- AuraGen Aesthetics
- Primary DI
- 00860003492703
- Version / Model
- 100358
- Company Name
- Auragen Aesthetics LLC
- Labeler DUNS
- 118060681
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-07-05
- Public Version
- 2
- Public Version Date
- 2021-07-14
- Public Version Status
- Update
- Public Device Record Key
- 1f8b7c70-9ab4-430f-92cf-f14f55ca0330
Device Description
AuraGen 1-2-3 with AuraClens - Lipoaspirate Wash System
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| QKL | Lipoaspirate Washing System For Aesthetic Body Contouring | General, Plastic Surgery | 878.5040 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 56627 | Autologous adipose tissue collection/washing set | A collection of sterile devices designed as a closed system for the harvesting and rapid treatment of autologous fat tissue for reinjection back into the patient from which it was taken for aesthetic body contouring. It typically consists of various chambers (e.g., a collection bag, waste material bag, and a cleaned tissue bag), flexible tubing, an intravenous (IV) spike for connection to the washing solutions, and a contiguous filter mesh which dialyses the fat graft. It is used in conjunction with appropriate IV solutions within the sterile field of intervention for plastic and reconstructive surgery and cosmetic surgery. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00860003492703 | GS1 |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| BK190433 | 0 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 4 – 30 Degrees Celsius