FDA UDI
In Commercial Distribution
🇺🇸 United States
Secure IM Nail
DI: 00857915007286
·
Model: 8960-65
·
A.M. SURGICAL, INC.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- Secure IM Nail
- Primary DI
- 00857915007286
- Version / Model
- 8960-65
- Company Name
- A.M. SURGICAL, INC.
- Labeler DUNS
- 160020087
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2019-11-14
- Public Version
- 3
- Public Version Date
- 2025-07-14
- Public Version Status
- Update
- Public Device Record Key
- e8686d92-fb65-4da3-96f4-0c1643005a97
Device Description
One 65mm x 1.6mm IM Nail
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HTY | Pin, Fixation, Smooth | Orthopedic | 888.3040 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 32854 | Orthopaedic bone pin, non-bioabsorbable | A thin, implantable rod intended to be used for the stabilization of a bone fracture or bone grafts, or for an osteotomy or arthrodesis (internal and/or external fixation). It is typically drilled into bone and may be smooth or threaded, solid or cannulated, and/or semi-flexible. Also known as a Kirschner-wire (K-wire), it may in addition be intended to assist with the introduction of a surgical instrument and/or implant; it is not intended for implantation into the intramedullary canal (i.e., not a nail). It is made of a non-bioabsorbable material (e.g., stainless steel). Some designs may have a break-off shank and/or be coated to improve long-term fixation. This is a single-use device. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00857915007286 | GS1 | ||||
| Package | 30857915007287 | GS1 | Case | 5 | In Commercial Distribution |
Customer Contacts
- Phone
- 631-979-9777
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K180087 | 000 |