FDA UDI In Commercial Distribution 🇺🇸 United States

Dualpro™ IVUS+NIRS Imaging Catheter Kit

DI: 00857595006234 · Model: TVC-C195-42 · INFRAREDX, INC.
Product Codes
2
GMDN Terms
1
Identifiers
2
Pkg Device Count
1

Basic Information

Brand Name
Dualpro™ IVUS+NIRS Imaging Catheter Kit
Primary DI
00857595006234
Version / Model
TVC-C195-42
Catalog Number
TVC-C195-42
Company Name
INFRAREDX, INC.
Labeler DUNS
124065421
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2018-07-11
Public Version
3
Public Version Date
2019-03-21
Public Version Status
Update
Public Device Record Key
7bbd4b2d-1743-40eb-86f6-1485b82980b7

Device Description

The Dualpro™ IVUS+NIRS Imaging Catheter Kit (TVC-C195-42) is a single use, disposable coronary catheter and accessory kit designed for use only with the Makoto Intravascular Imaging System™ (TVC-MC10 and TVC-MC10i). The dual-modality intravascular imaging catheter combines 50 MHz Extended Bandwidth IVUS transducer and laser-based near infrared spectroscopy (NIRS) for simultaneous acquisition of vessel structure and plaque composition data— a single catheter, a single pullback, two sets of data. The Dualpro™ IVUS+NIRS Imaging Catheter features a durable hydrophilic coating for improved deliverability. Indications for Use: 1. The Makoto Intravascular Imaging System™ is intended for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography. a. The System is intended for the detection of lipid-core-containing plaques of interest. b. The System is intended for the assessment of coronary artery lipid core burden. 2. The System is intended for ultrasound examination of coronary intravascular pathology. a. Intravascular ultrasound imaging is indicated in patients who are candidates for transluminal coronary interventional procedures.

Device Characteristics

Single Use
Yes
Prescription Use (Rx)
Yes
Over the Counter (OTC)
No
Kit
Yes
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
No
Has Serial Number
No
Has Lot/Batch Number
Yes
Has Manufacturing Date
No
Has Expiration Date
Yes
Has Donation ID
No

Sterilization

Is Sterile
Yes
Sterilization Prior Use
No

Product Codes

Code Name
IYO System, Imaging, Pulsed Echo, Ultrasonic
OGZ Catheter, Intravascular, Plaque Morphology Evaluation

GMDN Terms

Code Name
44141 Intravascular ultrasound imaging catheter, single-use

Identifiers

Type ID
Package 00857595006333
Primary 00857595006234

Customer Contacts

Phone
888-680-7339

Storage Conditions

Type
Storage Environment Temperature
Temperature Range
15 – 30 Degrees Celsius
Type
Special Storage Condition, Specify
Special Conditions
Keep dry
Type
Special Storage Condition, Specify
Special Conditions
Keep away from sunlight