FDA UDI
In Commercial Distribution
🇺🇸 United States
Transobturator Helical, Right Introducer
DI: 00857492008010
·
Model: CAL-HR32
·
Caldera Medical, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Transobturator Helical, Right Introducer
- Primary DI
- 00857492008010
- Version / Model
- CAL-HR32
- Catalog Number
- CAL-HR32
- Company Name
- Caldera Medical, Inc.
- Labeler DUNS
- 130341956
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2022-08-03
- Public Version
- 1
- Public Version Date
- 2022-08-11
- Public Version Status
- New
- Public Device Record Key
- 03192176-a4e1-4137-aa1f-f14979779c1c
Device Description
Transobturator Helical, 3.2mm, Right Introducer is a surgical mesh instrument to be used in surgical procedures for the insertion and placement of Desara surgical mesh.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| PWJ | Instrumentation, Surgical Mesh, Urogynecologic, Stress Urinary Incontinence | Obstetrics/Gynecology | 884.4910 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47442 | Transobturator needle, reusable | A hand-held manual surgical instrument with a sharp pyramidal or conical point intended to be used to create a percutaneous puncture using the transobturator approach (i.e., insertion points overlie the obturator space and the obturator foramen membrane is penetrated), for the surgical positioning of a sling used in the treatment of stress urinary incontinence (SUI), which may be associated with a prolapse. The distal working end is typically made of a stainless steel rod that is markedly curved or helicoidal (right- or left-angled), with a pointed tip and an eye or notch to help position the sling. The device can be made of metal and/or polymer materials. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00857492008010 | GS1 |
Customer Contacts
- Phone
- 1-818-879-6555
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K172614 | 000 |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Store wrapped instruments in a designated sterile supply area that protects sterile items and their packaging from damage. This area should be clean, dry and free of contaminants.