FDA UDI
Not in Commercial Distribution
🇺🇸 United States
MiroFlex®
DI: 00857072005002
·
Model: BLM-100-01-0608
·
REPRISE BIOMEDICAL, INC.
Product Codes
2
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- MiroFlex®
- Primary DI
- 00857072005002
- Version / Model
- BLM-100-01-0608
- Company Name
- REPRISE BIOMEDICAL, INC.
- Labeler DUNS
- 043611421
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-10-09
- Public Version
- 9
- Public Version Date
- 2023-10-04
- Public Version Status
- Update
- Public Device Record Key
- 00f0bc3d-2bb6-46af-8433-6fd0eb030aff
- Distribution End Date
- 2021-09-15
Device Description
Biologic Matrix
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FTM | Mesh, Surgical | General, Plastic Surgery | 878.3300 | 2 |
| OXH | Mesh, Surgical, Collagen, Plastic And Reconstructive Surgery | General, Plastic Surgery | 878.3300 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 60907 | Extra-gynaecological surgical mesh, collagen, bioabsorbable, non-antimicrobial | A bioabsorbable, implantable material (e.g., flat sheet) made from animal-derived collagen intended for extra-gynaecological, non-dental tissue repair/reinforcement application(s) [e.g., pericardial reinforcement, plastic surgery, abdominal hernia repair]; some types may also be intended for use as a short-term scaffold for tissue regeneration. It is constructed of collagen, which might be cross-linked (e.g., with glutaraldehyde); it does not include antimicrobial agents/materials. Disposable devices associated with implantation may be supplied with the mesh. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00857072005002 | GS1 |
Customer Contacts
- Phone
- 952-377-8238
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Height | 8 | Centimeter | |
| Width | 6 | Centimeter |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 2 – 30 Degrees Celsius