FDA UDI In Commercial Distribution 🇺🇸 United States

Pure EP - Catheter Input Module

DI: 00856750007048 · Model: PE-002-007-000 · BIOSIG TECHNOLOGIES, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1

Basic Information

Brand Name
Pure EP - Catheter Input Module
Primary DI
00856750007048
Version / Model
PE-002-007-000
Catalog Number
PE-002-007-000
Company Name
BIOSIG TECHNOLOGIES, INC.
Labeler DUNS
080048456
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2021-06-30
Public Version
1
Public Version Date
2021-07-08
Public Version Status
New
Public Device Record Key
f14aed9e-fb0a-46a8-ad4e-b3f3c861f2f0

Device Description

The Catheter Input Module - IC2 J-Box Bipolar Cable Assembly (3m) is an accessory to the PURE EP™ System. The catheter input modules are used for connecting the IC catheters to the amplifier (aka MSU - Main System Unit). The PURE EP™ is a system that consists of two main parts: the amplifier (aka MSU - Main System Unit), and the personal computer (PC), which are connected over a highspeed fiber optic cable. The patient is connected to the amplifier via a set of supplied ECG cables and commercially available intracardiac (IC) catheters. The amplifier includes hardware and embedded software necessary for acquiring ECG and IC signals from patients. The device is not intended for active patient monitoring. It consists of one ECG and seven IC modules designed to acquire 12-lead ECG and 56 IC signals and send the digitized data to the PC. The PC has preinstalled PURE-EP software and is connected to display monitors. The pre-installed software provides visualization of received data from the amplifier on real-time and review screens. It also includes a signal processing module that provides various filter options for real-time and review screens.

Device Characteristics

Single Use
No
Prescription Use (Rx)
No
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
No
Has Serial Number
No
Has Lot/Batch Number
Yes
Has Manufacturing Date
Yes
Has Expiration Date
No
Has Donation ID
No

Sterilization

Is Sterile
No
Sterilization Prior Use
No

Product Codes

Code Name
DQK Computer, Diagnostic, Programmable

GMDN Terms

Code Name
17898 Cardiac electrophysiology analysis system

Identifiers

Type ID
Primary 00856750007048

Customer Contacts

Premarket Submissions

Submission Number Supplement Number
K180805 000